This page identifies all you need to consider prior to your hot tub delivery. You will find the specific access dimensions and electrical requirements for your chosen model, along with relevant points to consider.

Aside from meeting the dimensional and electrical requirements, you will need an area of firm, level ground on which to site your spa.

The Hot Tub Superstore offers FREE Hot Tub Delivery and Installation across Mainland UK.

Example Delivery and Installation Video

When purchasing a new hot tub you will need to consider:

  • Access dimensions (varies between models)
  • Electrical requirements (varies between models)
  • Level ground (firm area)
  • Sufficient space

If you need any help or advice do not hesitate to call The Hot Tub Superstore team.

Width and Height

Our absolute minimum width and height requirements for each hot tub model are available on this page.

Please check the minimum width and height bearing in mind any possible obstructions — these typically include gate frames, window sills and drain pipes — to name but a few.

NOTE : Deliveries are completed using a Spa Dolly — a specific delivery trolley requiring minimal access. Consequently, all dimensions supplied are the minimum required, including the delivery system.

If you have any concern regarding your delivery, call our team on 01253 599330 and we will happily advise.

Electrical Requirements

13 AMP Requirements

13 amp models require an outdoor waterproof plug socket with RCD protection on a dedicated supply within 1.5 to 4 metres of the spa location.

32 AMP Requirements

These models require a 32-amp supply on HO7 6mm 3core cable with RCD protection (cable sizes may be different depending on the length of cable run between the consumer unit and commando socket). A commando socket with local isolation is required between 2 – 3 metres of the spa, complete with ‘male’ plug and 8 metres of ‘tail end’ (also HO7 6mm 3core cable.) The tail-end is hard-wired to the spa by our engineers, then simply plugged in to complete.

* The commando socket supply DOES NOT require your electrician present on installation. However, a 32 amp ‘hard-wired’ supply WILL REQUIRE YOUR ELECTRICIAN PRESENT ON INSTALLATION to complete the wiring connection.

A new RCD circuit breaker must be used for your spa installation. Do not use an existing breaker, as its condition is unknown. The spa must be connected to a dedicated RCD breaker that is not shared with any other equipment. Do not use an extension or plug type cords of any kind.

40 AMP Requirements

A 40 amp supply using HO7 6mm 3core cable with local isolation via rotary isolator, terminated with a 8 metre tail. A 40 amp breaker is required. The supply should feed directly from a suitable source (typically your domestic fuse box) to the rotary isolator which is typically mounted 2 metres from the spa area. An 8 metre ‘tail end’ is required from the isolator to the spa – the tail is ‘hard wired’ to the spa by an approved electrician*. Please note; the long tail is required to allow perfect siting and orientation of the spa.

*NOTE: THE 40 AMP SUPPLY ABOVE WILL REQUIRE YOUR ELECTRICIAN ON-SITE DURING THE INSTALLATION TO COMPLETE THE HARD WIRED CONNECTION.

Spa Dolly

The spa dolly is a specifically designed hot tub installation tool. The dolly holds the spa upright, minimising the space required, allowing a safe and hassle free installation.

Delivery Area

Access Requirements


MP LSX Range


Twilight 7.2, 7.25 & 8.2


Twilight 240, 6.2 & 67.25